Description
IP5X / IP6X Dust Chamber
Test Equipment:IEC 60529 IP5X and IP6X Dust Chamber (Figure 2 of IEC60529)
Model No.: IEC 60529 Figure 2
Applicable Standards: IEC 60529 for Enclosure Ingress Protection Test (IP Code)
Applications:Dust or solid foreign objects test for Outdoor equipment rated IP 5X or IP 6X.
Feature:
- Interior chamber: 80cm x 80cm x 80cm; or 100cm x 100cm x 100cm; or 120cm x 180cm x 120cm.
- Overall dimension: 90cm x 90xm x 180cm; or 110cm x 110xm x 190cm; 130cm x 190cm x 220cm.
- Viewing window: 60cm x 60cm min.
- Powder circulation pump is adjustable
- Dust Pumps/Vibrators: 2
- Talcum powder (Ø 75 micron) is available upon request.
- Evacuation (Under pressure) System for DUT, as required by IEC 60529
Specification:
See Figure 2 of IEC 60529
Dust Chamber Talcum Powder:
- TX0005 75 micron Talc (Agalite)
- 10 Kg Bucket / 1.55 Kg Container
- Standard IEC60529 Clause 13.4 specifies that talcum must be replaced every 20 tests.
- Standard IEC60529 Clause 13.4 specifies that dust volume must be 2 Kg / m3
Dust Chamber Talcum Powder:
- TX0005 75 micron Talc (Agalite)
- 10 Kg Bucket / 1.55 Kg Container
- Standard IEC60529 Clause 13.4 specifies that talcum must be replaced every 20 tests.
- Standard IEC60529 Clause 13.4 specifies that dust volume must be 2 Kg / m3
Model |
Container Weight |
DTC-810 |
10 KG |
DTC-825 |
1.55 KG |